Invasive
|
Non-Invasive
|
|
Ventilator Mode |
VC-CMV
VC-ACMV PC-CMV PC-ACMV PC-SIMV PRVC-ACMV |
HFNC
CPAP CPAP-PS BiPAP-S/T BiPAP-PS |
Control Parameters |
Tidal Volume
PIP (Peak Inspiratory Pressure) I-PAP PEEP (Positive End Expiratory Pressure) EPAP/CPAP CPAP-PS FiO2 Breath Rate Per minute I TIME Apnea Backup Rate HFT – High Flow Therapy |
100-1800 mL
5-70 cmH2o 5-40 cmH2o 0& 5-30 cmH2o 5-30 cmH2o 5-30 cmH2o 21-100% 4-40 bpm 0.1-3.0 sec 4-40 BPM 20-70 LPM |
Display Parameters |
Respiratory Rate
Minute Ventilation Lpm Tidal Volume Fio2 Airway Pressure (Min, Mean, Max) Plateau Pressure Inspiratory Pressure Flow Airway Flow (For High ow Therapy) Airway Temperature (For High ow Therapy) |
BPM
LPM mL % cmH2o cmH2o cmH2o LPM LPM ˚C |
Alarms | 1) Disconnect (for Patient Tubing) 2) PEEP 3) Tidal Volume 4) P insp 5) Flow Alarm 6) Temperature Alarm 7) Respiratory Rate |
8) FiO2 9) Machine Fault 10) Low Power (for Alarm Battery) 11) E-PAP 12) C-PAP 13) I-PAP |
Monitoring Display |
Numerical Display
Vertical Bar Chart Volume, Pressure & Flow Digital 7 inch Graphical Display* |
–
|
Oxygen Sensor |
Optical/Ultrasonic Oxygen Sensor
Accuracy + 2% @100% FiO2 With Auto Calibration |
21-100%
|
Gas Supply |
Air source Inlet
Oxygen Source High Pressure Diss Input |
Built – In Blower
Range 35 to 87 PSI |
Electrical Specification |
Ac Supply
Battery |
110 -240 VAC, 90 W Max,
50/60 Hz 9 v Alarm Battery |
Special Function |
Automatic System Self-test On Start up
Alarm Silence Reset Electronic PEEP Tablet Based Alarm Data Log* Tablet Based Trending Data Storage* Patient Vital Report Generation 24 x 7 x 365 Inbuilt Air Source Zero Risk of Cross Contamination to patient Medical Air as Per European Standards |
Flow Sensor Auto Calibration
Oxygen Sensor Auto Calibration Blower Driven Pressure Trigger Automatic leakage compensation Non-invasive Modalities Permanent Oxygen Sensor Automatic Altitude Compensation |
Safety |
Electrical Safety IEC 60601-1, IEC 60601-2
Relief Valve for Excessive Pressure Cut-off Alternate Breathing Airway In case of machine failure Safety Valve |
–
|
Dimensions |
Size L x W X H (mm)
Weight (Kg) |
440 x 340 x 310
9.2 KG |
Product |
EV Electra Ventilator
Power Cord 7 Inch Tablet with Mount and Interface Cable High Pressure Diss Female Oxygen Hose IPPB Patient Tubing Set with Bacterial Hme Filter Bipap Mask Adult Test Lung 1 Litre Operating User Manual |
1
1 1 1 1 1 1 1 |
Optional Accessories |
UPS 110 /230 v 50/60 Hz 100 W
Complete Stand Assembly Circuit Support Arm for Holding Patient Tubing |
–
|
GET REMOTE ACCESS TO CUSTOMIZED HEALTH CARE APP :
• Provide live feed of ventilator to your mobile
• Monitors alarm indications along with trigger count
• Export data in PDF format
• Detail reports along with time stamp
• Stores patient profile with data log
• Data portability via SD card
• Provides graphic representation of tidal volume and proximal pressure
In built Blower & Permanent Sensor :
A common challenge with some turbine-driven
ventilators is the lack of power to deliver
constant flow and high pressure over a sustained
time period. Interruptions may occur due to a
need to switch devices, modes, batteries,
cylinders – or even to replace a broken turbine.
Electra delivers steady ICU performance and
flow with unusually high power.
Incorporated with economical solution of world
class permanent mass flow sensor and oxygen sensor with auto calibration facility.
USB Controller Nebuliser Compatible :
USB controlled effective aerosol drug delivery
system to patient in high flow invasive and non
invasive modalities.
Maintaining patient closed circuit drug delivery
system for aersol to eliminate need of open
circuit.
HFNC :
High Flow therapy (HFNC) comprises an active humidifier, a single heated circuit, and a nasal cannula. It
delivers adequately heated and humidified medical gas at up to 70 L/min of flow and is considered to have a
number of physiological effects: reduction of anatomical dead space, PEEP effect, constant fraction of
inspired oxygen, and good humidification. While there have been no big randomized clinical trials, it has been
gaining attention as an innovative respiratory support for critically ill patients With Airway Over Temperature
Protection Feature.
Clinical applications with Electra :
- BIPAP Machine :
BiPap machine can help push air into your lungs and it can be used to provide treatment for a wide range of respiratory
conditions.
• Chronic Obstructive Pulmonary Disorder (COPD)
• Obesity Hypoventilation Syndrome (OHS)
• Obstructive Sleep Apnea
• Central Sleep Apnea
- CPAP Machine :
A continuous positive airway pressure (CPAP) machine is
the most effective treatment for sleep apnea, a common
sleep disorder in which breathing is interrupted throughout
the night. Sleep apnea can decrease your quality of life and
contribute to cardiovascular disease and events such as
heart attack and stroke.
Reviews