Volume Controlled Ventilation |
VC-CMV
VC-AC VC-SIMV PRVC-CMV PRVC-AC PRVC-SIMV |
---|---|
Pressure Controlled Ventilation |
PC-CMV
PC-AC PC-SIMV |
Spontaneous Breathing Support |
PS/CPAP (PSV) with Apnea Backup Ventilation
APRV HFNC * |
Therapy type |
Invasive Ventilation
Non-invasive Ventilation (NIV) O₂ therapy |
Types of Patients Supported |
Adults and Paediatric
|
Apnea Backup Ventilation | |
High Flow Nasal Oxygen Therapy |
Pressure Measurements |
Peak Inspiratory Pressure (PIP)
Positive end Expiratory Pressure (PEEP) Plateau Pressure ( Pplat) Driving Pressure Mean Pressure ( Pmean ) Range: 0 to 100 cm O₂ |
---|---|
Flow Measurements |
Expiratory minute Volume ( M Ve )
Inspiratory minute Volume ( M Vi) Spontaneous Expired minute Volume ( Spont. M Ve ) Range 0 to 160 L/min |
Volume Measurements |
Inspiratory Tidal Volume ( V Ti )
Expiratory Tidal Volume ( V Te ) Total Leak Volume |
Other Measurements |
Oxygen Concentration ( FiO2 )
Respiratory Rate (RR) I:E Ratio Rapid Shallow Breathing Index (RSBI) Static Lung Compliance ( Cstat ) Dynamic Lung Compliance ( Cdyn ) Inspiratory Time ( Ti ) Expiratory Time ( Te ) |
Trends |
Storage of trends for last 48 hours of all parameters
|
Respiratory Rate (RR) |
1 – 60 BPM
|
---|---|
Peak Inspiratory Pressure |
50 cm of H₂O
|
PEEP |
0 – 50 cm of H₂O
|
Pressure Support |
0 – 50 cm of H₂O
|
Inspiratory Time (Ti) | 0.2 – 5 s |
I:E Ratio | 1:6 to 6:1 |
Tidal Volume (VT) | 50 – 2000 mL |
Inspiratory Flow Rate | 280 L/min (Internally restricted to 160 L/min) |
Trigger Flow Sensitivity | 1 – 20 L/min |
Volume Accuracy | 2 – 3% of full scale between 10 L/min – 80 L/m |
O₂ Concentration (FiO₂) | 21 – 100 % |
FiO₂ Control | Closed loop electronic manipulation |
Recruitment Tools |
Inspiration Hold
Expiration Hold |
Leak Detection and Compensation | Upto 200 ml |
O₂ Therapy | Continuous flow 0 – 80 L/min Concentration 21 – 100 % |
Nebulizer | for 5, 6, 7, 8, 9, 10 minutes Synced with Inspiratory Phase * |
Oxygen Input | 45 – 60 PSIG |
Screen | 10” TFT LCD Touchscreen |
Dimensions Patient Unit | 395 X 340 X 255 mm |
Weight | ~ 10.1 Kg Patient Unit ~ 25 Kg with trolley |
Battery |
Lithium, Internal
|
Battery Back-up Time | Upto 8 hours |
Mains Input | 200 – 240V AC, 50 – 60 Hz |
Input Current | <2.00 A |
Power Consumption | <150W |
Alarms for Patient Safety |
PEEP (High / Low)
Respiratory Rate (High / Low) Tidal Volume (High / Low) FiO₂ (High / Low) High Inspiratory Pressure Patient Disconnection Battery Low |
---|---|
Alarm Features |
Color coded alarms based on priority
Adjustable Apnea Alarm time ( Tapnea ) History of last 200 alarms |
UNIQUE FEATURES :
- High Flow Oxygen Therapy HFNC Mode
- 10 inch Touchscreen with User-friendly Interface
- 8 Hours Battery Backup
- Inbuilt Programmable Nebulizer Synced with Inspiratory Phase*
- IoT Enabled Central Data Monitoring and Logging**
Reviews
There are no reviews yet.